Sensoray 618 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Sensoray 618. Sensoray 618 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - PCI Smart A/D Cards

Sensoray Models 618/619PCI Smart A/D CardsRevised May 12, 1999

Strany 2 - Table of Contents

Sensoray Model 618/619 Smart A/D 8 Sensor ConnectionsIf you are using a six-wire gage, you should connect the gage’s excitation source and excitation

Strany 3 - 1 Basics

Sensoray Model 618/619 Smart A/D 9 Programming5 ProgrammingThe Smart A/D board is programmed by means of a small, yet powerful built-in command set.

Strany 4 - 2 Introduction

Sensoray Model 618/619 Smart A/D 10 Programminghardware and software, are available through the GetFaultFlags function.For details on this function, r

Strany 5 - 3 Configuration

Sensoray Model 618/619 Smart A/D 11 ProgrammingChannel sensor types remain at the default setting until changed by this function. If the default sens

Strany 6 - 3.5 Fault Indicator

Sensoray Model 618/619 Smart A/D 12 Programming5.4.2 GetSensorDataReturns the most recently acquired sensor data from one sensor channel. The returne

Strany 7 - 4 Sensor Connections

Sensoray Model 618/619 Smart A/D 13 Programmingnegative with respect to LowLimit, while the channel alarm is armed.The HighLimit and LowLimit argument

Strany 8 - Four-wire connection

Sensoray Model 618/619 Smart A/D 14 ProgrammingTypically, this function is invoked just before a call to SetGageSpan. Together, the SetGageZero and Se

Strany 9 - 4.6 Thermocouples

Sensoray Model 618/619 Smart A/D 15 Calibration6 CalibrationSmart A/D boards are factory calibrated to meet or exceed published specifications. Beca

Strany 10 - 4.8 4-to-20 mA Current Loops

Sensoray Model 618/619 Smart A/D 16 Theory of Operation7 Theory of Operation7.1 FirmwareThe Smart A/D’s internal microcomputer executes a firmware-r

Strany 11 - 5 Programming

Sensoray Model 618/619 Smart A/D 17 Timing8 TimingThree timing parameters are important from the application developer’s viewpoint: Channel Update R

Strany 12 - 10 Programming

Sensoray Model 618/619 Smart A/D Table of ContentsTable of ContentsBasics...1Introduction ...

Strany 13 - 11 Programming

Sensoray Model 618/619 Smart A/D 18 Timing8.3 Data AgeData Age is the measure of time that has elapsed since a channel’s data was acquired by the Sma

Strany 14 - 5.5 Alarm Functions

Sensoray Model 618/619 Smart A/D 19 Specifications9 Specifications9.1 General Specifications Table 6: General SpecificationsCategory Parameter Condi

Strany 15 - 13 Programming

Sensoray Model 618/619 Smart A/D 20 Specifications9.2 Sensor SpecificationsNotes1. Measurement resolution and accuracy is specified for the default (

Strany 16 - 14 Programming

Sensoray Model 618/619 Smart A/D 1 Basics1 Basics1.1 Limited WarrantySensoray Company, Incorporated (Sensoray) warrants the Model 618/619 hardware t

Strany 17 - 6 Calibration

Sensoray Model 618/619 Smart A/D 2 Introduction2 Introduction2.1 Functional DescriptionSensoray models 618 and 619 Smart A/D boards provide eight (m

Strany 18 - 7 Theory of Operation

Sensoray Model 618/619 Smart A/D 3 Configuration3 ConfigurationThe Smart A/D board requires the configuration of programming shunts to select hardwar

Strany 19 - 8 Timing

Sensoray Model 618/619 Smart A/D 4 Configuration3.3 Shunt LocationsThe diagram below shows the locations of hardware programming shunts on the Smart

Strany 20 - 8.4 Communication Latency

Sensoray Model 618/619 Smart A/D 5 Sensor Connections4 Sensor Connections4.1 OverviewSensors are connected to the Smart A/D by means of 40-pin heade

Strany 21 - 9 Specifications

Sensoray Model 618/619 Smart A/D 6 Sensor Connections4.3.2 Excitation TerminalsPassive sensors require connection to the I+ and I- signals. The I+ an

Strany 22 - 9.2 Sensor Specifications

Sensoray Model 618/619 Smart A/D 7 Sensor ConnectionsThermistors have much higher resistance values than RTDs over most of their operating range. Cons

Příbuzné modely 619 | 718 |

Komentáře k této Příručce

Žádné komentáře